Close

PCR Biosystems launches advanced Bst Polymerase reagents for accelerated DNA and RNA amplification

Note* - All images used are for editorial and illustrative purposes only and may not originate from the original news provider or associated company.

Related stories

When to Bring in Outside Help for FDA Cybersecurity Compliance (and What to Look For)

Medical device cybersecurity has become too important to treat...

Billerud Introduces New Pharmaceutical Packaging Option

Billerud has officially introduced PharmaKraft, a specialized fibre-based packaging...

AstraZeneca Advances AI Drug Discovery Deal with insitro

AstraZeneca has inked a billion-dollar AI drug discovery partnership...
- Advertisement -

PCR Biosystems, the UK-based specialists in DNA and RNA analysis, have launched a range of IsoFast™ Bst Polymerase reagents for rapid, robust and sensitive DNA and RNA amplification. Through its nucleic acid strand displacement capabilities, Bst polymerase eliminates the need for the high temperature denaturation step associated with traditional Taq enzymes. This enables faster time to result and facilitates DNA and RNA amplification in the field without specialised thermocycling equipment.

The new range of IsoFast Bst reagents from PCR Biosystems can be used for a variety of techniques including whole genome amplification, multiple displacement amplification and isothermal amplification. Such techniques have important applications in sectors ranging from environmental and food pathogen testing to clinical diagnostics and next generation sequencing. Scientists performing DNA and RNA amplification using IsoFast Bst Polymerase can benefit from consistent results over a wide dynamic range and sensitivities down to 3 copies of target DNA (10fg).

To continue PCR Biosystems’s support of the global fight against COVID-19, the Bst Polymerase reagents have been validated for qualitative detection of the SARS-CoV-2 nucleic acid. Combined with the reagents’ suitability for use in the field, this validation opens the potential for rapid SARS-CoV-2 testing in environments such as airports, hospitals or care homes, without the need for a central laboratory, delivering results in 30 minutes and supporting initiatives for community or regular testing to safeguard public health. Sensitivities down to 12 copies of SARS-CoV-2 targets can be achieved, providing confidence in the quality and accuracy of results.

“DNA and RNA amplification has been a staple technique in the scientific toolbox for more than 40 years, and with its application for SARS-CoV-2 diagnostic testing, there has been an increased demand for rapid and reliable reagents for mass testing,” says Alex Wilson, Co-Founder of PCR Biosystems. “The launch of the IsoFast Bst Polymerase range aligns with our commitment to provide robust solutions to support COVID-19 testing and will continue to expand diagnostic capabilities for viruses such as Zika and Ebola long after the COVID-19 pandemic.”

While many supply chains have been disrupted due to the pandemic, PCR Biosystems continues to scale up and optimise operations to provide consistent, reliable supplies to customers, ensuring laboratories have the critical DNA and RNA analysis reagents needed for uninterrupted research and diagnostics.

The IsoFast Bst range is available in flexible formats, with 2X mix formats streamlining set up for high throughput applications and components available separately for those customers wanting to optimise the reaction for their specific needs. Furthermore, the reagents are offered with optional fluorescent dyes, facilitating real-time amplification tracking.

About PCR Biosystems
PCR Biosystems is a London-based UK manufacturer of PCR kits and reagents for molecular biology diagnostics and research. Founded in 2012 by two PCR experts, the company has developed a range of PCR and associated reagents that maximise speed and sensitivity from the simplest to most challenging of reactions. The company’s portfolio covers a broad range of applications including hot start PCR, long range PCR, high fidelity PCR, PCR direct from crude samples and molecular diagnostic PCR. ISO 13485:2016 certification means customers have the assurance that products and processes meet the required standards and regulations for the manufacturing of medical device components. PCR Biosystems offers a broad range of standard and custom solutions including bulk supply of reagents, OEM manufacturing and expert technical support to help customers achieve the most from their market-leading enzymes. Today, PCR Biosystems has an international team and a global network of distributors supplying customers in over 37 countries worldwide.

Never miss a pharmaceutical headline

The pharmaceutical industry moves fast – stay on top of it with our must - read briefings.

  • The top pharma and life sciences stories, straight to your inbox
  • The biggest news, features, interviews, and analysis
  • Dedicated coverage of the key developments driving the global pharmaceutical sector

Subscribe

- Never miss a story with notifications

- Gain full access to our premium content

- Browse free from any location or device.

Media Packs

Expand Your Reach With Our Customized Solutions Empowering Your Campaigns To Maximize Your Reach & Drive Real Results!

– Access the Media Pack Now

– Book a Conference Call

– Leave Message for Us to Get Back

Latest stories

Related stories

When to Bring in Outside Help for FDA Cybersecurity Compliance (and What to Look For)

Medical device cybersecurity has become too important to treat...

Billerud Introduces New Pharmaceutical Packaging Option

Billerud has officially introduced PharmaKraft, a specialized fibre-based packaging...

AstraZeneca Advances AI Drug Discovery Deal with insitro

AstraZeneca has inked a billion-dollar AI drug discovery partnership...

Managing Quality and Regulatory Risks in Pharmaceutical Technology Transfer

Technology transfer moves more than manufacturing instructions. It moves process knowledge, supplier dependencies, labeling requirements, packaging specifications, and the evidence needed to demonstrate control. For medical device manufacturers, including those supporting drug-device combination products, these interfaces can become recurring sources of compliance gaps during site transitions, acquisitions, and remediation. The central problem is often not a missing procedure. It is a quality system that allows connected activities to change independently. A label revision may be approved while packaging artwork, supplier instructions, or production-system data still reflect an obsolete version. Staying inspection-ready requires manufacturers to manage these dependencies as one controlled system. Why Compliance Gaps Keep Recurring Findings are treated as documentation defects Revising a procedure can resolve an immediate discrepancy without changing the behavior that caused it. If unclear decision rights, weak escalation, or ineffective training remain, the same failure may surface elsewhere. Corrective and preventive action should distinguish the observed finding from its underlying cause and establish how effectiveness will be demonstrated. Ownership is divided across connected functions Quality, Regulatory Affairs, labeling, packaging engineering, operations, suppliers, and digital-system owners often maintain separate workflows. Each team may complete its assigned task while an interface remains uncontrolled. For example, changing an instruction for use can affect packaging configuration, translations, technical documentation, inventory disposition, and release controls. Transitions expose unresolved weaknesses Acquisitions and site transfers can introduce conflicting procedures, incomplete knowledge transfer, or different assumptions about validated processes. Regulatory changes add further demands. When these events coincide with CAPA or change-control backlogs, teams may prioritize administrative closure over risk reduction. Without a coordinated impact assessment, local fixes can create new gaps downstream. Establish the Regulatory Baseline Inspection readiness starts with knowing which requirements apply to the product, activity, and market. Pharmaceutical, device, and combination-product obligations are not interchangeable; transfer planning should identify the applicable requirements rather than assume one quality framework covers every operation. According to FDA’s Quality Management System Regulation overview and FAQs, the QMSR became effective on February 2, 2026, incorporates ISO 13485:2016 by reference, and introduced the updated device inspection process under Compliance Program 7382.850. ISO 13485 certification does not exempt a manufacturer from FDA inspection or guarantee compliance with FDA requirements. For devices marketed in the European Union, Regulation (EU) 2017/745, Annex I, Section 23, provides the primary requirements for information supplied with devices, including labels and instructions for use. Teams should assess the applicable provisions alongside relevant language, product-specific, and market requirements. A labeling review should therefore evaluate required content and consistency with the device’s intended purpose and supporting documentation—not merely artwork accuracy. How to Identify the Real Gaps Begin with a cross-functional assessment that follows actual product and information flows. Select representative transfers, label changes, supplier changes, and CAPAs, then trace each from initiation through implementation and effectiveness review. Map dependencies: Identify affected specifications, suppliers, packaging components, systems, validation activities, and training. Compare records with practice: Check whether approved procedures match what operators and reviewers actually do. Test traceability: Follow a requirement through technical documentation, labeling, production instructions, and release evidence. Examine recurrence: Look for repeated deviations, reopened actions, overdue changes, and findings shared across sites. Assess capacity: Determine whether qualified owners have enough time and authority to complete corrective work. Prioritize gaps by potential patient or user harm, regulatory impact, likelihood of recurrence, and detectability. Document the rationale; an old overdue item is not automatically more important than a newly identified high-risk weakness. Align Quality, Labeling, Packaging, and Change Control Create a coordinated remediation plan with one accountable owner for each action, named contributors, acceptance criteria, and required evidence. Separate immediate containment from systemic correction. Containment might prevent obsolete labels from being issued; correction might redesign approval and implementation controls so obsolete versions cannot return. Use change control as the integration point. Before approval, evaluate effects on regulatory submissions or notifications, technical documentation, supplier controls, packaging performance, validation, electronic master data, inventory, and training. Record both identified impacts and justified decisions that particular activities are unaffected. During technology transfer, define readiness gates before production or release responsibilities move. These should address the transfer of process knowledge, acceptance criteria, receiving-site capability, required qualification or validation, approved documents, and personnel competence. The appropriate evidence depends on the product and process; a generic checklist cannot replace a documented assessment. Finally, verify implementation where the work happens. Confirm that current instructions are available, suppliers received approved requirements, systems contain correct versions, and affected personnel can perform their tasks. A signed approval is not evidence that every downstream change took effect. Mistakes That Undermine Inspection Readiness Closing CAPAs on task completion alone: Effectiveness checks should test whether the underlying failure has been controlled. Updating labels in isolation: Assess packaging, supplier, system, documentation, and inventory consequences. Counting closures instead of evidence: Dashboards need defensible records behind their status indicators. ...

Subscribe

- Never miss a story with notifications

- Gain full access to our premium content

- Browse free from any location or device.

Media Packs

Expand Your Reach With Our Customized Solutions Empowering Your Campaigns To Maximize Your Reach & Drive Real Results!

– Access theMedia Pack Now

– Book a Conference Call

– Leave Message for Us to Get Back

Translate »